Your Professional Residual Current Circuit Breaker Supplier!

 

Founded in 2010, Zhejiang Westroom Electric Co., Ltd. has a registered capital of 10 million RMB and is a professional enterprise integrating the design, manufacturing, sales, and service of plastic-cased circuit breakers, residual current circuit breakers, miniature circuit breakers, and other related products.The company primarily produces plastic-cased circuit breakers, residual current circuit breakers, miniature circuit breakers, and other related products.

 

 
 

Why Choose Us

Stable Quality

Equipped with advanced production and testing facilities, Westroom Electric implements strict quality control throughout the manufacturing process. This helps ensure reliable product performance, consistent quality, and stable supply for long-term projects.

Our Service

Westroom Electric is focuses on providing responsive pre-sales, in-sales, and after-sales support to ensure customer satisfaction throughout the cooperation process.

Sales Market

The company supplies products to power transmission and distribution engineering companies, agents, and project contractors in Europe, the United States, Japan, the Middle East, Russia, and Southeast Asia, as well as the domestic market.

 

Overview: Residual Current Circuit Breaker

 

 

A Residual Current Circuit Breaker (RCCB)—also called RCD or GFCI—is a device that protects people from fatal electric shock. Unlike MCBs, which guard against overloads and short circuits, RCCBs detect tiny current leaks that may flow through the human body.

 

Product Specification
 

We offers the following product specifications:

Item

Specification

Rated Current

25A, 40A, 63A, 80A, 100A

Number of Poles

1P (+N), 2P, 3P (+N), 4P

Rated Voltage

230/400VAC

Rated Insulation Voltage

500V

Rated Frequency

50/60Hz

Short-Time Withstand Current (Icw)

12Ie, 1s

Making & Breaking Capacity

3Ie, 1.05Ue

Rated Short-Circuit Making Capacity

20Ie, t = 0.1s

Rated Impulse Withstand Voltage

6000V

Mechanical Life

8,000 cycles

 

Leakage Current Circuit Breaker

 

Product Features

Easy to install - Terminals equipped with fail-safe features to avoid improper installation. A double slot for connection with cables and PS busbars. Possible to connect two independent cables in the same device.

 

Contact position indicator (CPI) - To always know the status of the contacts independently on the toggle position. Red: closed contacts, green: open contacts.

 

Test pushbutton - To verify the correct functioning of the device.

 

Integration - Compatible with System pro M Compact accessories.

 

Marking on the device - All the safety ensured by the international marks: approvals' marking in a visible area, even if RCDs are installed and with the panel-door closed.

 

Common types

 

AC

Detects and trips on alternating sinusoidal residual currents.

01

A

Detects both alternating and pulsating direct residual currents.

02

B

Suitable for detecting smooth direct residual currents, often used in industrial applications.

03

F

Designed for applications where both AC and DC residual currents are present, such as in variable speed drives.

04

H

Offers increased sensitivity for enhanced protection in critical environments.

05

 

Precautions

 

RCCB With Overcurrent Protection

Routine Testing

Test the residual current circuit breaker regularly using the built-in test button. This helps ensure the device is functioning properly. It's recommended to test it every 3 months.

DC RCCB factory

Visual Inspection

Periodically inspect the RCCB for signs of wear, such as damage to the device or signs of overheating.

RCCB With Overcurrent Protection suppliers

Replacement

If the RCD switch fails to trip during testing or shows signs of damage, it should be replaced immediately by a qualified professional.

 

Components

 

Phase wire (A): The phase wire is the live wire, or hot wire, that sends current from the power supply to the circuit.

Breaker contacts (B): The breaker contacts are closed or open to control whether current can pass through the RCCB or not, respectively.

 

Neutral wire (C): The neutral wire sends current back to the power source.

Test button (D): The test button lets users quickly test whether the circuit breaker is functioning correctly. Pushing the button stops the flow of electricity through the breaker.

 

Current limiting resistor (E): When the test button is pressed, current flows directly through the neutral wire from the phase wire. The resistor prevents the current from getting too high.

Sensing coil (F): The sensing coil wraps around the core and determines whether there is a balance or imbalance between the phase and the neutral.

 

Core (G): The core is made of ferrous material. Some core designs have a plastic cover for insulation and protection. Currents from the phase and neutral wires create opposing magnetic fields. The sensing coil monitors whether there is a difference between the two latter currents.

Relay (H): When there is an imbalance between the phase and neutral, the relay causes the breaker contacts to open.

Application
 
DC RCCB
 

Residential Installations

Homes remain the most common application of RCCB. Kitchens, bathrooms, and outdoor sockets are especially vulnerable. The device cuts the supply instantly, reducing shock risk.

 

Industrial Safety Systems

Factories deal with high-powered motors and long cable networks. Here, the application of RCCB becomes critical for worker safety. Installing multiple RCCBs across distribution boards helps isolate faults quickly.

DC RCCB suppliers
Leakage Current Circuit Breaker high quality
 

Construction and Temporary Sites

In such situations, an RCCB circuit breaker acts as a frontline protector. Portable RCCB units are often attached to extension boards to prevent fatal shocks. It's a small investment compared to the massive safety benefits it delivers.

 

Commercial Buildings

Shopping malls, offices, and hotels rely on uninterrupted power. Yet safety cannot be compromised.Strategic RCCB placement allows fault isolation without triggering widespread inconvenience.

Leakage Current Circuit Breaker suppliers

 

Other Services

Advanced Arc-Extinguishing Technology

Features an optimized arc chute design that rapidly interrupts fault currents in milliseconds, minimizing thermal and mechanical stress on downstream equipment.

Versatile Trip Unit Options

Available with high-precision electronic or reliable thermal-magnetic trip units. Adjustable current settings allow for precise matching to specific load profiles.

High Breaking Capacity, Compact Footprint

Delivers exceptional short-circuit breaking capacity (Icu/Ics) within a compact frame. This space-saving design optimizes panel layout and reduces overall enclosure costs.

 

Field-Installable Modular Accessories

Easily accommodates snap-on accessories—including shunt trips, undervoltage releases (UVR), auxiliary contacts, and alarm switches—to support complex control logic and remote monitoring.

 

 

Certifications

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
 

Package & Delivery

 

Package: Standard export package or Custom
Delivery: By air express, by sea

 

productcate-1-1

 

 

FAQ

 

Q: What is RCCB?

A: A Residual Current Circuit Breaker (RCCB) is an electrical protecting device that protect against the leakage current and prevents electric shock and fire hazards in an electrical circuit. RCCB detect the leakage current and fastly trip the circuit by cutting off the power supply. It is easy to install.

Q: What is the residual current circuit breaker (RCCB) used for?

A: RCCBs are used for:
Protecting human life against electric shocks from direct or indirect contact with live parts.
Preventing electrical fires caused by earth leakage currents.
Domestic, commercial, and industrial application.

Q: Which RCCB is better, 30mA or 100mA?

A: 30mA RCCB: It is best for personal protection because it trips quickly to protect from electric shock. Mostly used in homes and offices.
100mA RCCB: It is Less sensitive & suitable for equipment and fire protection. It is used where some level of leakage current is normal.

Q: Why does RCCB always trip?

A: RCCB trip because of earth leakage due to faulty wiring or insulation.
If there is Moisture in appliances or connections.
Overloaded neutral wires or shared neutrals causing imbalance.
Incorrect RCCB rating.

Q: Are you manufacturer or trading company?

A: We are manufacturer.

Q: What's your best delivery time?

A: Within 15-30 days.

Q: What is the quality control of your product?

A: Follow strictly quality control measures for implementation,

Q: Will your company provide free sample?

A: It depends on which sort of item you want to get. Some can be provided free of charge, however, the client shall assume the shipping fees himself.

Q: Is OEM open to clients?

A: Yes, we can provide both OEM and ODM service.

Q: What is the payment of sample?

A: T/T and Alipay both acceptable.

Q: What is your packing?

A: Yes, our packaging is genuine original packaging. Of course, we can also provide neutral packaging or according to your requirements

Q: What is your sample policy?

A: If we have stock, we can provide samples, but the customer must pay the sample fee and express fee Question

Q: Have you tested all your goods before shipment?

A: Yes, we will conduct 100% test before delivery, and we will send detailed photos of parts for your approval .

Q: How can you maintain a long-term good relationship with our business?

A: We maintain good quality and competitive prices to ensure the interests of our customers.

As one of the leading residual current circuit breaker manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to wholesale advanced residual current circuit breaker at competitive price from our factory.

Current Operated Circuit Breaker, Residual Current Breaker with Overcurrent Protection, Residual Circuit Breaker with Overload

Shopping Bags